alcon inc
acrysof sn60wf ![]() Acrysof Sn60wf, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/intraocular+lens+acrysof%C2%AE+iq+sn60wf/acrysof+sn60wf/pmc06087024-36-67-69 Average 90 stars, based on 1 article reviews
acrysof sn60wf - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
Johnson & Johnson
monofocal aspheric iols ![]() Monofocal Aspheric Iols, supplied by Johnson & Johnson, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/intraocular+lens+acrysof%C2%AE+iq+sn60wf/iol+piece+single/pmc12503799-88-62-65 Average 86 stars, based on 1 article reviews
monofocal aspheric iols - by Bioz Stars,
2026-10
86/100 stars
|
Buy from Supplier |
|
alcon inc
yellow-tinted acrysof sn60at lenses ![]() Yellow Tinted Acrysof Sn60at Lenses, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/intraocular+lens+acrysof%C2%AE+iq+sn60wf/iol+sn60at/pm25627184-122-11-16 Average 90 stars, based on 1 article reviews
yellow-tinted acrysof sn60at lenses - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
alcon inc
blf iol sn60wf/au00t0 ![]() Blf Iol Sn60wf/Au00t0, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/intraocular+lens+acrysof%C2%AE+iq+sn60wf/acrysof/pmc10284132-51-37-39 Average 90 stars, based on 1 article reviews
blf iol sn60wf/au00t0 - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
alcon inc
one-piece foldable iol acrysof iq sn6ad1 ![]() One Piece Foldable Iol Acrysof Iq Sn6ad1, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/intraocular+lens+acrysof%C2%AE+iq+sn60wf/acrysof+restor+sn6ad1/pm27918824-72-1-9 Average 90 stars, based on 1 article reviews
one-piece foldable iol acrysof iq sn6ad1 - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
Alcon Japan Ltd
iol acrysof sn60wf ![]() Iol Acrysof Sn60wf, supplied by Alcon Japan Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/intraocular+lens+acrysof%C2%AE+iq+sn60wf/acrysof+restor++2+5+d++sn6ad2/pmc05995481-81-1-4 Average 90 stars, based on 1 article reviews
iol acrysof sn60wf - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
alcon inc
one-piece acrylic iol ![]() One Piece Acrylic Iol, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/intraocular+lens+acrysof%C2%AE+iq+sn60wf/one+piece+acrylic+iol/pmc09948424-123-19-31 Average 90 stars, based on 1 article reviews
one-piece acrylic iol - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
alcon inc
envista mx60 ![]() Envista Mx60, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/intraocular+lens+acrysof%C2%AE+iq+sn60wf/envista+mx60/pmc06553733-123-40-29 Average 90 stars, based on 1 article reviews
envista mx60 - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
alcon inc
iol alcon t6 series ![]() Iol Alcon T6 Series, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/intraocular+lens+acrysof%C2%AE+iq+sn60wf/iol+alcon+t6+series/10__2147_slash_opth__s296032-40-6-12 Average 90 stars, based on 1 article reviews
iol alcon t6 series - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
alcon inc
clareon cna0t0 ![]() Clareon Cna0t0, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/intraocular+lens+acrysof%C2%AE+iq+sn60wf/clareon+cna0t0/pm40507667-60-10-43 Average 90 stars, based on 1 article reviews
clareon cna0t0 - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
alcon inc
diffractive trifocal iol tfnt00 ![]() Diffractive Trifocal Iol Tfnt00, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/intraocular+lens+acrysof%C2%AE+iq+sn60wf/tfnt00/pmc08976350-28-13-19 Average 90 stars, based on 1 article reviews
diffractive trifocal iol tfnt00 - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
|
Nidek CO
iol nidek ns60yg ![]() Iol Nidek Ns60yg, supplied by Nidek CO, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/intraocular+lens+acrysof%C2%AE+iq+sn60wf/aktis+sp+ns+60yg/pmc07602541-45-7-27 Average 90 stars, based on 1 article reviews
iol nidek ns60yg - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Clinical Ophthalmology (Auckland, N.Z.)
Article Title: Evaluation of anterior capsular contraction syndrome after cataract surgery with commonly used intraocular lenses
doi: 10.2147/OPTH.S172251
Figure Lengend Snippet: Eyes with ACCS risk factors
Article Snippet: – For example, it is well established that silicone IOLs lead to a greater degree of capsule contraction than acrylic IOLs., Additionally, a number of risk factors have been identified that are associated with an increased risk of ACCS, including pseudoexfoliation (PXE) syndrome, uveitis, retinitis pigmentosa, history of retinal surgery, and diabetes., We compared the incidence of ACCS between two most commonly used hydrophobic acrylic lenses, the
Techniques:
Journal: Clinical Ophthalmology (Auckland, N.Z.)
Article Title: Evaluation of anterior capsular contraction syndrome after cataract surgery with commonly used intraocular lenses
doi: 10.2147/OPTH.S172251
Figure Lengend Snippet: Patient demographics and ACCS incidence
Article Snippet: – For example, it is well established that silicone IOLs lead to a greater degree of capsule contraction than acrylic IOLs., Additionally, a number of risk factors have been identified that are associated with an increased risk of ACCS, including pseudoexfoliation (PXE) syndrome, uveitis, retinitis pigmentosa, history of retinal surgery, and diabetes., We compared the incidence of ACCS between two most commonly used hydrophobic acrylic lenses, the
Techniques:
Journal: Clinical Ophthalmology (Auckland, N.Z.)
Article Title: Evaluation of anterior capsular contraction syndrome after cataract surgery with commonly used intraocular lenses
doi: 10.2147/OPTH.S172251
Figure Lengend Snippet: Lens specifications
Article Snippet: – For example, it is well established that silicone IOLs lead to a greater degree of capsule contraction than acrylic IOLs., Additionally, a number of risk factors have been identified that are associated with an increased risk of ACCS, including pseudoexfoliation (PXE) syndrome, uveitis, retinitis pigmentosa, history of retinal surgery, and diabetes., We compared the incidence of ACCS between two most commonly used hydrophobic acrylic lenses, the
Techniques: Modification
Journal: PLoS ONE
Article Title: The influence of low signal-to-noise ratio of axial length measurement on prediction of target refraction, achieved using IOLMaster
doi: 10.1371/journal.pone.0217584
Figure Lengend Snippet: The comparison of mean numeric errors between 3 kinds IOLs.
Article Snippet: Notably, a previous study reported that there was no significant difference in postoperative refraction according to types of aspheric and acrylic IOLs manufactured by Abbott Medical Optics Inc. and
Techniques:
Journal: BMC Ophthalmology
Article Title: Influence of implantation of diffractive trifocal intraocular lenses on standard automated perimetry
doi: 10.1186/s12886-022-02372-4
Figure Lengend Snippet: Demographic data and postoperative visual acuity in eyes with trifocal and monofocal intraocular lenses
Article Snippet: Patients who underwent cataract surgery with implantation of a diffractive trifocal IOL or
Techniques:
Journal: BMC Ophthalmology
Article Title: Influence of implantation of diffractive trifocal intraocular lenses on standard automated perimetry
doi: 10.1186/s12886-022-02372-4
Figure Lengend Snippet: Box plots of mean deviation (left) and foveal sensitivity (right) for 10–2 grid standard automated perimetry in eyes with trifocal and monofocal intraocular lenses (IOLs) in the current study. The mean deviation and foveal sensitivity with monofocal IOLs are significantly higher than those with trifocal IOLs ( P < 0.021)
Article Snippet: Patients who underwent cataract surgery with implantation of a diffractive trifocal IOL or
Techniques:
Journal: BMC Ophthalmology
Article Title: Influence of implantation of diffractive trifocal intraocular lenses on standard automated perimetry
doi: 10.1186/s12886-022-02372-4
Figure Lengend Snippet: Box plot of mean deviation for 10–2 grid standard automated perimetry in eyes with monofocal, diffractive trifocal, extended depth of focus (EDOF), and bifocal intraocular lenses (IOLs) obtained in previous and current studies. The mean deviation values associated with the use of the trifocal IOLs are lower than those for the use of the monofocal IOLs ( P = 0.027, t-test with Holm’s multiple comparisons), not different from those for the use of EDOF IOLs, and higher than those for the use of bifocal IOLs ( P = 0.035)
Article Snippet: Patients who underwent cataract surgery with implantation of a diffractive trifocal IOL or
Techniques:
Journal: Materials
Article Title: Measurement of Force Required for Anterior Displacement of Intraocular Lenses and Its Defining Parameters
doi: 10.3390/ma13204593
Figure Lengend Snippet: The six Intraocular lens (IOL) models used in this experiment. All are one-piece, soft-acrylic, +20-D refractive force, 6-mm optics diameter. ( a ) HOYA XY-1, ( b ) HOYA 255, ( c ) J&J ZCB00V, ( d ) Alcon SN60WF, ( e ) KOWA YP2.2, and ( f ) Nidek NS60YG.
Article Snippet: In this study, 18 IOLs representing six
Techniques:
Journal: Materials
Article Title: Measurement of Force Required for Anterior Displacement of Intraocular Lenses and Its Defining Parameters
doi: 10.3390/ma13204593
Figure Lengend Snippet: Summary of IOL models.
Article Snippet: In this study, 18 IOLs representing six
Techniques: Refractive Index
Journal: Materials
Article Title: Measurement of Force Required for Anterior Displacement of Intraocular Lenses and Its Defining Parameters
doi: 10.3390/ma13204593
Figure Lengend Snippet: Experimental settings. ( a ) Setting for the IOL displacement force measurement. The forces required for anterior displacement of the IOLs. The IOLs set in the fixture are displaced anteriorly (anterior chamber side) by a pusher from the posterior (vitreous cavity) side until the IOL optics move 1 mm in the water. The water temperature is set at 35 °C. ( b ) The setting for the IOL hardness measurement. The IOL is indented by the indenter perpendicular to the center of the optics. ( c , d ) The settings for the string lengths ( c , pink double arrow) and thickness ( d , pink double arrow) measurements of the haptics/optics junction area. ( e , f ) The settings for the posterior IOL bulge measurement. The IOLs are set in a clear cylinder with an inner diameter of 10 mm ( e ), and the distance between the rubber disc surface and surface of the IOL (red double arrow) is measured.
Article Snippet: In this study, 18 IOLs representing six
Techniques:
Journal: Materials
Article Title: Measurement of Force Required for Anterior Displacement of Intraocular Lenses and Its Defining Parameters
doi: 10.3390/ma13204593
Figure Lengend Snippet: Forces required for anterior displacement of each IOL model (mN).
Article Snippet: In this study, 18 IOLs representing six
Techniques:
Journal: Materials
Article Title: Measurement of Force Required for Anterior Displacement of Intraocular Lenses and Its Defining Parameters
doi: 10.3390/ma13204593
Figure Lengend Snippet: Difference in forces required for anterior IOL displacement among the various IOL models.
Article Snippet: In this study, 18 IOLs representing six
Techniques:
Journal: Materials
Article Title: Measurement of Force Required for Anterior Displacement of Intraocular Lenses and Its Defining Parameters
doi: 10.3390/ma13204593
Figure Lengend Snippet: IOL hardness, haptics junction area, and posterior IOL bulge in each IOL model.
Article Snippet: In this study, 18 IOLs representing six
Techniques: